# DS18B20_raspi ## Read first https://pinout.xyz/pinout/1_wire https://www.raspberrypi-spy.co.uk/2018/02/enable-1-wire-interface-raspberry-pi/ For grafana Influx: https://pimylifeup.com/raspberry-pi-grafana/ https://pimylifeup.com/raspberry-pi-influxdb/ ## Hardware Connect the DS18B20 to the raspberry pi Raspi - DS18B20 3V3 -> VIN GND -> GND GPIO 4 -> DATA Rember to add a 4K7ohm pull-up resistor between VIN and DATA on the sensor! ## REQUIRED PACKAGES python3-influxdb ## Installation Enable i2c in raspi-config Copy the files (as root!) report_temperature.service/report_temperature.timer from ./etc/systemd/system to your system /etc/systemd/system Now tell systemd that you have added new files: 'systemctl daemon-reload' save temperature_reporter.py to /home/pi/tempsense/. Enable and start the timer: 'systemctl enable report_temperature.timer --now' ## Store script at a differet location. If you want the script to be stores elsewhere (not in /home/pi/tempsense/.) then you have to edit the file (as root!) /etc/systemd/system/report_temperature.service Just change the line: ExecStart=/home/pi/tempsense/temperature_reporter.py ## Configure the script before running. in temperature_reporter.py comfigure: ' INFLUX_IP = "" INFLUX_PORT = 8086 INFLUX_DB = "" INFLUX_USER = "" INFLUX_PASS = "" ' You can give the sensors costum names to be reoported by configuring the in the device names: device_names = {"28-000000000000":"Sensor_Name"}